9XCite ‐ PKG ‐ R? ? RS ‐ 232/485 ? RF ? Modem ? – ? Product ? Manual ? v2.1 ? [2007.01.04]
CS (DO2 Configuration) Command
<AT Command: Serial Interfacing> CS Command
is used to modify the behavior of the CTS signal
such that it either provides RS-232 flow control,
AT Command: ATCS
Parameter Ranges: 0 - 4
enables RS-485 transmission / reception or deter-
mines RS-422 transmit enable. By default, CTS
provides RS-232 flow control. CS Parameter must
be adjusted for the modem to operate in RS-485/
422 environments.
Parameter
0
1
2
3
4
Configuration
Normal CTS
RS-485 enable (low)
high
RS-485 enable (high)
low
Default Parameter Value: 0
Number of bytes returned: 1
CT (Time before Exit AT Command Mode) Parameter
<Non-AT Settable Parameter: AT Command Options> AT Command Mode can be exited manually
using CN (Exit AT Command Mode) Command or, after a given time of inactivity, the modem exits
AT Command Mode on its own and return to Idle Mode. CT Command sets the amount of time
before AT Command Mode is exited automatically. If no characters are received before this time
elapses, the modem will return to Idle Mode.
Parameter Range: 0x02 - 0xFFFF [x 100 ms]
# of bytes returned: 2
Default Parameter Value: 0xC8 (200d (20 decimal seconds))
DB (Receive Signal Strength) Command
<AT Command: Diagnostic> DB Parameter returns the receive signal strength (in decibels) of the
last received packet. This Parameter is useful in determining range characteristics of the XCite
Modules under various conditions.
AT Command: DB
Parameter Range: 0x25 - 0x6A [Read-only]
# of bytes returned: 1
DT (Destination Address) Command
<AT Command: Networking> DT Command is used to set the address of the XCite Radio Modem.
XCite Radio Modems use three network layers - the Vendor Identification Number (ATID), Chan-
nels (ATHP) and Destination Addresses (ATDT).
DT Command assigns an address to a radio modem that enables it to communicate only with radio
modems that have matching addresses. This is similar to interconnecting several PCs under a
common hub. All radio modems that share the same destination address can communicate freely
with each other. Radio Modems in the same network with a different destination address (than that
of the transmitter) will listen to all transmissions to stay synchronized, but will not send any of the
data out their serial ports.
AT Command: DT
Parameter Range: 0 - 0xFFFF
# of bytes returned: 2
Default Parameter Value: 0
Related Commands: ID (Modem ID), HP (Channel), MK (Address Mask)
? ? 2007 ? MaxStream, ? Inc.
????? 25
相关PDF资料
XC0900A-03S COUPLER 90DEG 811-1000MHZ 3DB
XC1900A-03S COUPLER 90DEG 1700-2000MHZ 3DB
XC2401A8167R-G IC GPS LNA 1.6GHZ USPN-4B02
XC2404A816UR-G IC GPS LNA 1.6GHZ USP-8A01
XE112 LAMP T3-1/4 WITH XE GAS WHITE
XE1203SKC868XE2 KIT STARTER FOR XE1203 868MHZ
XE1205SKC868XE1 KIT STARTER FOR XE1205 868MHZ
XE1283I076TRLF IC TXRX UHF LOW POWER 72-LFBGA
相关代理商/技术参数
XC09-038WNC 功能描述:射频模块 9XCite 4mW transcei e antenna 38400 bps RoHS:否 制造商:Linx Technologies 产品:Transceiver Modules 频带:902 MHz to 928 MHz 输出功率:- 15.5 dBm to + 12.5 dBm 接口类型:UART 工作电源电压:- 0.3 VDC to + 5.5 VDC 传输供电电流:38.1 mA 接收供电电流:22.7 mA 天线连接器类型:U.FL 最大工作温度:+ 85 C 尺寸:1.15 mm x 0.63 mm x 0.131 mm
XC09-038WNI 功能描述:射频模块 9XCite 4mW transcei e antenna 38400 bps RoHS:否 制造商:Linx Technologies 产品:Transceiver Modules 频带:902 MHz to 928 MHz 输出功率:- 15.5 dBm to + 12.5 dBm 接口类型:UART 工作电源电压:- 0.3 VDC to + 5.5 VDC 传输供电电流:38.1 mA 接收供电电流:22.7 mA 天线连接器类型:U.FL 最大工作温度:+ 85 C 尺寸:1.15 mm x 0.63 mm x 0.131 mm
XC-09-201-S 制造商:FLOYD BELL 功能描述:Alarm, Piezoelectric, 82 dBA to 103 dBA @ 2 Ft.,Extra Loud Continuous, 30-120VAC
XC-09-212-S 制造商:FLOYD BELL 功能描述:EXTRA LOUD CONTINUOUS, PANEL MOUNT CASE AND QUICK CONNECT BLADES WITH SCREWS TER
XC-09-212-SR 制造商:FLOYD BELL 功能描述:Alarm, Piezoelectric, 82 dBA to 103 dBA @ 2 Ft., Extra Loud Continuous, 2-12VDC
XC-09-212-W 制造商:FLOYD BELL 功能描述:EXTRA LOUD CONTINUOUS; PANEL MOUNT CASE AND WIRES TERMINATION
XC-09-301-S 制造商:FLOYD BELL 功能描述:Alarm, Piezoelectric, 82 dBA to 103 dBA @ 2 Ft.,Extra Loud Continuous,130-220VAC
XC-09-330-Q 制造商:FLOYD BELL 功能描述:EXTRA LOUD CONTINUOUS; PANEL MOUNT CASE AND QUICK CONNECT BLADES TERMINATION